<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UTP Cable &#8211; RAINICT</title>
	<atom:link href="https://www.rainict.com/product-category/network/utp-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.rainict.com</link>
	<description>ONE-STOP ICT Solution Provider</description>
	<lastBuildDate>Fri, 06 Feb 2026 00:24:48 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.rainict.com/wp-content/uploads/2025/04/cropped-Rainict-Logo-Orange-32x32.png</url>
	<title>UTP Cable &#8211; RAINICT</title>
	<link>https://www.rainict.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Rosenberger CAT.6 UTP Cable 305M (Original)</title>
		<link>https://www.rainict.com/product/rosenberger-cat-6-utp-cable-305m-original/</link>
					<comments>https://www.rainict.com/product/rosenberger-cat-6-utp-cable-305m-original/#comments</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 22 Apr 2025 17:19:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.rainict.com/?post_type=product&#038;p=11613</guid>

					<description><![CDATA[<h4>Key Features:</h4>
Model: Rosenberger CAT.6 UTP Cable 305M
155 Mbit /622Mbit /1.2 Gbit ATM
100 Mbps TP-PMD
TR-16 Active and Passive]]></description>
										<content:encoded><![CDATA[<h3>Rosenberger Cat6 UTP Cable 305M | CP11-141-12-BL:</h3>
<ul>
<li>CAT.6 data cable for structured premise cabling transmits voice, data, and video signals.</li>
<li>It supports current high-bandwidth applications, especially suitable for the application of Fast-Ethernet.</li>
<li>These indoor and outdoor cat.6 UTP cables are designed for an unshielded cabling system.</li>
<li>These CAT.6 cables exceed the requirements of TIA-568-C.2 and ISO/IEC11801-2nd- Edition with significant margins on all parameters.</li>
<li>It is available with different jacket materials of various flame-retardant levels.</li>
</ul>
]]></content:encoded>
					
					<wfw:commentRss>https://www.rainict.com/product/rosenberger-cat-6-utp-cable-305m-original/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>PANDUIT NETKEY CAT6 U/UTP CABLE BOX OF 305 MT (ORIGINAL)</title>
		<link>https://www.rainict.com/product/netkey-cat6-u-utp-cable-box-of-305-mt-original/</link>
					<comments>https://www.rainict.com/product/netkey-cat6-u-utp-cable-box-of-305-mt-original/#comments</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 22 Apr 2025 16:39:35 +0000</pubDate>
				<guid isPermaLink="false">https://www.rainict.com/?post_type=product&#038;p=11606</guid>

					<description><![CDATA[<strong>Key Features</strong>
Brand: Panduit
100% Copper, Origin: USA,
Model: Cat6 UTP Cable
Jacket material: PVC
Product Type: Copper Cable
Insulation Material: HDPE, Color: Blue]]></description>
										<content:encoded><![CDATA[<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-d29d035" data-id="d29d035" data-element_type="column">
<div class="elementor-widget-wrap elementor-element-populated">
<div id="SeagateBarraCudaQ51TB" class="elementor-element elementor-element-7d06e20 elementor-widget elementor-widget-wd_text_block" data-id="7d06e20" data-element_type="widget" data-widget_type="wd_text_block.default">
<div class="elementor-widget-container">
<div class="wd-text-block reset-last-child text-left">
<h4>Specification</h4>
<table class="table table-sm table-striped" width="802">
<tbody>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Environment</td>
<td class="pl-2 border-all border-block">Indoor</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Performance Level</td>
<td class="pl-2 border-all border-block">Category 6</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Cable Construction</td>
<td class="pl-2 border-all border-block">U/UTP</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Flammability Rating</td>
<td class="pl-2 border-all border-block">CM</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">EuroClass Rating</td>
<td class="pl-2 border-all border-block">Eca</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">LP Rating</td>
<td class="pl-2 border-all border-block">NA</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Resistance Properties</td>
<td class="pl-2 border-all border-block">Flame Retardant</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Jacket Material</td>
<td class="pl-2 border-all border-block">Polyvinyl Chloride (PVC)</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Nominal Cable Outside Diameter (In.)</td>
<td class="pl-2 border-all border-block">0.222</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Nominal Cable Outside Diameter (mm)</td>
<td class="pl-2 border-all border-block">5.6</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Maximum Operating Temperature (°C)</td>
<td class="pl-2 border-all border-block">60</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Maximum Operating Temperature (°F)</td>
<td class="pl-2 border-all border-block">140</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Minimum Operating Temperature (°C)</td>
<td class="pl-2 border-all border-block">60</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Minimum Operating Temperature (°F)</td>
<td class="pl-2 border-all border-block">140</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Maximum Installation Temperature (°C)</td>
<td class="pl-2 border-all border-block">50</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Maximum Installation Temperature (°F)</td>
<td class="pl-2 border-all border-block">122</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Minimum Installation Temperature (°C)</td>
<td class="pl-2 border-all border-block">0</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Minimum Installation Temperature (°F)</td>
<td class="pl-2 border-all border-block">32</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Sub Brand</td>
<td class="pl-2 border-all border-block">NetKey®</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Maximum Installation Tension (lb)</td>
<td class="pl-2 border-all border-block">25</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Maximum Installation Tension (N)</td>
<td class="pl-2 border-all border-block">110</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Bend Radius (In.)</td>
<td class="pl-2 border-all border-block">0.888</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Bend Radius (mm)</td>
<td class="pl-2 border-all border-block">22</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Number of Pairs</td>
<td class="pl-2 border-all border-block">4</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Conductor Material</td>
<td class="pl-2 border-all border-block">Copper</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Conductor Type</td>
<td class="pl-2 border-all border-block">Solid</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Overall Length</td>
<td class="pl-2 border-all border-block">305M</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Conductor Gauge (AWG)</td>
<td class="pl-2 border-all border-block">24</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Insulation Material</td>
<td class="pl-2 border-all border-block">HDPE</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Acidity Rating</td>
<td class="pl-2 border-all border-block">NA</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Insulation Diameter (In.)</td>
<td class="pl-2 border-all border-block">0.036</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Insulation Diameter (mm)</td>
<td class="pl-2 border-all border-block">0.92</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Maximum Voltage (V)</td>
<td class="pl-2 border-all border-block">80</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Standards Met</td>
<td class="pl-2 border-all border-block">Exceeds ISO 11801 Class E and ANSI/TIA-568.2-D Category 6, IEC 61156-5, UL 1685, EN 50575: Euroclass Eca, meets IEEE 802.3af, IEEE 802.3at and IEEE 802.3bt for PoE applications, RoHS Compliant.</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Color</td>
<td class="pl-2 border-all border-block">Blue</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Flaming Droplets Rating</td>
<td class="pl-2 border-all border-block">NA</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Overall Length (ft.)</td>
<td class="pl-2 border-all border-block">1000</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Packaging Type</td>
<td class="pl-2 border-all border-block">Easy Payout Carton</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Product Type</td>
<td class="pl-2 border-all border-block">Copper Cable</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Smoke Rating</td>
<td class="pl-2 border-all border-block">NA</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">EuroClass Flame Rating</td>
<td class="pl-2 border-all border-block">Eca</td>
</tr>
<tr>
<td class="pl-2 border-all table-column-width border-block pdt-td-border-top">Part Features</td>
<td class="pl-2 border-all border-block">100% copper cable</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-e5e93c9" data-id="e5e93c9" data-element_type="column">
<div class="elementor-widget-wrap elementor-element-populated">
<div class="elementor-element elementor-element-cc5360a elementor-widget elementor-widget-wd_text_block" data-id="cc5360a" data-element_type="widget" data-widget_type="wd_text_block.default">
<div class="elementor-widget-container">
<div class="wd-text-block reset-last-child text-left">
<h4>Brief Description</h4>
<p><strong>Technical Information</strong><br />
<strong>Electrical performance:</strong> Certified channel performance in a 4-connector configuration up to 100 meters and meets ISO 11801 Class E and ANSI/TIA-568-C.2 Category 6 standards at swept frequencies up to 250MHz.<br />
<strong>Conductors/ insulators:</strong> 24 AWG solid copper insulated with polyolefin<br />
<strong>Flame rating: </strong>EN 50575: Euro class B2ca-s1a-d1-a1<br />
<strong>PoE compliance:</strong> Meets IEEE 802.3af, IEEE 802.3at and IEEE 802.3bt for PoE applications<br />
<strong>Installation tension: </strong>110 N (25 lbf)<br />
<strong>Temperature rating:</strong> -20º C to 75º C (-4º F to 167º F) during operation 0º C to 50º C (32º F to 122º F) during installation<br />
<strong>Cable jacket:</strong> LSFRZH<br />
<strong>Cable diameter:</strong> 5.9 mm (0.235 inches) nominal Cable weight:12 kg/305 m (26 lbs./1000 ft.)<br />
<strong>Packaging:</strong> 305 m (1000 ft.) easy payout carton</p>
<p><strong>Key features and benefits</strong><br />
<strong>Easy payout carton: </strong>Ensures proper performance and provides quick installation<br />
<strong>Third-party testing: </strong>Cable has been tested as part of the NetKey™ Category 6 U/UTP Copper Cabling System by an independent laboratory and complies with the electrical channel requirements of the following standards: ISO 11801 Class E and ANSI/TIA-568-C.2 Category 6<br />
<strong>Descending length cable marking</strong>: Easy identification of remaining cable reduces installation time and cable scrap<br />
Robust design: Cross divider separates twisted pairs for robust cable design</p>
<p><strong>Applications</strong><br />
NK6™ U/UTP Copper Cable is a component of the Panduit NK6™ U/UTP Copper Cabling System. This end-to-end system provides Gigabit Ethernet performance with usable bandwidth beyond 250MHz. With the certified performance of the ISO 11801 Class E and ANSI/TIA-568-C.2 Category 6 standards, this system will support the following applications:</p>
<p>* Ethernet 10BASE-T<br />
*100BASE-T (Fast Ethernet)<br />
*1000BASE-T (Gigabit Ethernet)</p>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.rainict.com/product/netkey-cat6-u-utp-cable-box-of-305-mt-original/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
	</channel>
</rss>
